The necessity of steel structure anticorrosion in power industry
The power industry presents extreme operational challenges, with high-temperature and highly corrosive environments causing traditional coatings to fail through cracking, blistering, and delamination. This is particularly evident in flue gas desulfurization (FGD) systems, where critical components - absorbers, scrubbers, duct outlets, mixing chambers, and flues - face aggressive corrosion from acid condensates, chlorides, and abrasive wear.
These corrosive mechanisms are accelerated by thermal cycling, dew point fluctuations, wet-dry transitions, high gas velocities, and concentrated sulfate/fluoride/chloride solutions, leading to severe pitting and crevice corrosion in stainless steel components.
Substation Steel Structure Coating Reference System >>
|
Examples Of Painted Parts
|
Protection Plan
|
Road Number
|
Thickness(μm)
|
|
Substation steel structure surface
|
Surface pretreatment
|
Sandblasting and rust removal reach Sa2.5 level
|
|
|
Cold galvanizing compound primer
|
2
|
80-120
|
|
|
High-temperature pipelines in substations
|
Surface pretreatment
|
Sandblasting and rust removal reach Sa2.5 level
|
|
|
Silicone high temperature resistant paint
|
1
|
60
|
|
Thermal Power Plant Steel Structure Coating Reference System >>
|
Examples Of Painted Parts
|
Protection Plan
|
Road Number
|
Thickness(μm)
|
|
Air cooling platform/coal shed grid
|
Surface pretreatment
|
Sandblasting and rust removal reach Sa2.5 level
|
|
|
Cold galvanizing compound primer
|
2
|
100
|
|
|
Silver metallic finish
|
1
|
20
|
|
|
Boiler bracket
|
Surface pretreatment
|
Sandblasting and rust removal reach Sa2.5 level
|
|
|
Cold galvanizing compound primer
|
1
|
80
|
|
|
Cold galvanizing compound sealant 80um
|
1
|
80
|
|
|
Polyurethane finish 70um
|
1
|
70
|
|
Solar Steel Structure Coating Reference System >>
|
Examples Of Painted Parts
|
Protection Plan
|
Road Number
|
Thickness(μm)
|
|
Solar steel structure surface
|
Surface pretreatment
|
Sandblasting and rust removal reach Sa2.5 level
|
|
|
Cold galvanizing compound primer
|
2
|
80-120
|
|
| Silver metallic finish |
1
|
60
|
|
Power Steel Structure Maintenance Coating Reference System >>
|
Examples Of Repaired Painted Parts
|
Protection Plan
|
Road Number
|
Thickness(μm)
|
|
Air-cooled/Boiler Support/Suspended Suite/Coal Conveying Station Shed/Grid
|
Surface pretreatment
|
Sandblasting and rust removal reach Sa2.5 level
|
|
| Cold galvanizing compound primer | 1 | 80-120 | |
|
Epoxy Mica Intermediate Paint
|
1 | 60-80 | |
| Fluorocarbon topcoat |
1
|
60
|
|
Power Industry Coating Cases